    KathieRNRV Repair Club:
    April 6, 2020OK, so looking for some advice/information. I am currently in a campground with only 30 amp service My electric heat pump will not run on this service. It is a basement unit. My gas furnace is working fine so not cold (as long as I don't run out of pr...  more
    • BLSMSS (Brenda &Marc) and 2 others like this.
    • KathieRN
      travellinglee April 6, 2020 Portable or not, to do a comparable job as your on-board kit will require a comparable amount of power.  Have you considered getting a 50 amp generator instead, that way you can use your existing kit plus it means you can get your 50amps for other ki...  more
    • KathieRN
      Paul & Kay Legare April 6, 2020 My heat pumps will not function below 37 degrees. Might that be your issue. I don't know how cold your part of WV gets
    • KathieRN
      Barry & Millie-Ambassadors April 6, 2020 Heat pump and ac same power supply amd should run on 30 amp
    • KathieRN
      TeamFoxy April 6, 2020 What is the breaker size for the AC / heatpump? We can run one, but not two, of our A.C. units on 30A service. You may also have to limit using other items like water heater or microwave when using A.C. Also be aware that heat pumps don't work below a cer...  more
    • KathieRN
      pokeysRVadventures April 6, 2020 @ Paul & Kay, It's 43 there right now and will be in the 30's this week. Those temps could be the problem.
    • KathieRN
      KathieRN April 6, 2020 OK, apparently I didn't make myself very clear.  I have a 50 amp RV plugged into 30 amp service and no the temps are not the problem.  It will start up but shut off as if the temps are too cold but they are not.  It is a basement heat pump,...  more
      Hide 1 Reply
      • KathieRN
        pokeysRVadventures April 6, 2020 Possibly 30 Amps is not enough power to run the heater or AC with the type of unit that you have.
    • KathieRN
      John T April 6, 2020 Kathie RN, great questions, here's an old retired n rusty power engineers response: "However, my question is, if my heat pump isn't working, does this mean my air conditioner won't work either - they are the same unit." ...  more
      Hide 1 Reply
      • KathieRN
        pokeysRVadventures April 6, 2020 What you posted pretty much covers it all. Not enough power or the temps for that type of unit.
    • KathieRN
      JLF April 6, 2020 My basement air doesn't include a heat pump function, but it does have two compressors in the one unit.  Inside an upper cabinet there is a switch labelled 50 amp that when switched off allows use on 30 amp service by only allowing one compressor to ...  more
    • KathieRN
      Steve&Barb April 6, 2020 There us an adapter that connects two 30 amp together to make a 50 amp female receptacle. 14-50R available at Amazon
      Hide 1 Reply
      • KathieRN
        JLF April 6, 2020 If anyone is having trouble locating the part using 14-50R, which is just the NEMA number for a 50 amp receptacle, they can narrow their search to "RV 14995" in "Automotive Parts and Accessories".
    • KathieRN
      John T April 6, 2020 Kathie, thanks for the update "I have a 50 amp RV plugged into 30 amp service and no the temps are not the problem.  It will start up but shut off as if the temps are too cold but they are not." NOT being there to collect any d...  more
    • KathieRN
      Samuel Smith April 6, 2020 I have a Winnebago (1999) 50 amp basement unit.  When I am in a campground with 30 amp, I shut off my rear air compressor and the 30 amp runs the front air and distributes through all coach air vents. I have to watch what else is plugged in so I don'...  more
    • KathieRN
      Joe On The Go RV Tech April 6, 2020 I like to preserve my propane so I bought a small electric heater and use it anytime I am plugged in. :)
    • KathieRN
      ColoradoCindy April 6, 2020 I am find that a fan cools off my rv if the temperatures aren't too extreme.
    • KathieRN
      Glen & Margie April 6, 2020 Where 30amp only is available, make sure to set your water heater to propane. Then you should be able to run your air unit without a problem. If you use your microwave be sure and turn off
      the AC or you will pop the breaker.
      Hide 1 Reply
    • KathieRN
      pymmint April 6, 2020 I’m not sure I understand the actual “setup” of the OP, I just know I have a furnace than runs off propane AND a heat setting on my thermostat, which come from the same unit as my AC, whenever I tried to run it, I just got cold air, so it never helped at ...  more
      Hide 1 Reply
      • KathieRN
        MRJohnston April 6, 2020 The Heat Pump is probably working.  It does not function well or at all (blows cold air) below about 40°F as there just is not enough heat left in the air to extract (unless you have an electric strip heat pump).  Also, when turning on the Heat ...  more
    • KathieRN
      Jim & Sharon Ham April 6, 2020 If we assume the RV is really a 50amp power cord that is being reduced to 30amp outlet with an adapter plug, the problem is in the RV internal wiring.  The 50amp service would have two 110 volt hot legs, but the 30amp only 1 hotleg.  Sounds like...  more
      Hide 1 Reply
      • KathieRN
        pymmint April 6, 2020 When I've been on 30amp, I can run one of my two ac units, but not both at the same time; so at night is turn off the "main/living room one and turn on the bedroom. I never had any prob with either one, one at a time.
    • KathieRN
      John T April 6, 2020 Kathie, when you state "It will start up but shut off" that says to me: 1) It, via your 30 to 50 Amp adapter (ifffffffff that's how you're connecting your 50 amp 4 pin plug RV to a 30 Amp 3 Pin receptacle)  IS IT ????...  more
      Hide 1 Reply
      • KathieRN
        KathieRN April 6, 2020 It worked a week ago when plugged into 50 amp pedestal so I just don't think I can draw enough power to run it right now.
    • KathieRN
      John T April 7, 2020 Kathie, thanks for the update "It worked a week ago when plugged into 50 amp pedestal so I just don't think I can draw enough power to run it right now. "
      Hide 1 Reply
      • KathieRN
        John T April 7, 2020 YOU MAY WELL BE RIGHT !!!!!!!!!!!!!!!!!!!!!!!!!!!!! As a PS to my above most recent post, In the event your unit DID HAVE backup resistive heat ??? in the event the temps were too low to extract enough heat and iffffff...  more
    • KathieRN
      Yawn April 17 Hi KathieRN I have a 5th wheel and last summer we was camping at Twin Knobs. My husband forgot to bring the 50 amp plug so we hooked up to the 30 and nothing wouldn't work in my camper so he went home and got the adapter for the 50 amp and it worked. My c...  more
    • KathieRN
      KathieRN April 17 Thanks all for the advice - my air conditioner did work in the summer time so I am guessing that it was just the fact that it didn't have enough power on the 30 amp service. I won't make that mistake again!!!  It is a pain in the butt to fill the propane ...  more
    Read more from RV Repair Club Group
  • RV BUG STOP
    SPONSORED POST

    The self-closing design on the R.V Bug Stop keeps the slider on the R.Vs screen door closed. Installation is simple and requires no tools. just pull off the film from the tape and attach it to the horizontal rail under the slider. no more yelling at someone for leaving the slider open. with no bugs coming in you can sit back and relax thanks to the R. V. Bug Stop.